Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 46(18): e2300373, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37582640

RESUMO

Nano-liquid chromatography (nanoLC) is gaining significant attention as a primary analytical technique across various scientific domains. Unlike conventional high-performance LC, nanoLC utilizes columns with inner diameters (i.ds.) usually ranging from 10 to 150 µm and operates at mobile phase flow rates between 10 and 1000 nl/min, offering improved chromatographic performance and detectability. Currently, most exploration of nanoLC has focused on particle-packed columns. Although open tubular LC (OTLC) can provide superior performance, optimized OTLC columns require very narrow i.ds. (< 10 µm) and demand challenging instrumentation. At the moment, these challenges have limited the success of OTLC. Nevertheless, remarkable progress has been made in developing and utilizing OTLC systems featuring narrow columns (< 2 µm). Additionally, significant efforts have been made to explore larger columns (10-75 µm i.d), demonstrating practical applicability in many situations. Due to their perceived advantages, interest in OTLC has resurged in the last two decades. This review provides an updated outlook on the latest developments in OTLC, focusing on instrumental challenges, achievements, and advancements in column technology. Moreover, it outlines selected applications that illustrate the potential of OTLC for performing targeted and untargeted studies.

2.
Molecules ; 28(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37446660

RESUMO

Graphene oxide sheets fixed over silica particles (SiGO) and their modification functionalized with C18 and endcapped (SiGO-C18ec) have been reported as sorbents for extraction and analytical columns in LC. In this study, a SiGO column was selected as the extraction column and a SiGO-C18ec as the analytical column to study the applicability and limitations of a column-switching system composed exclusively of columns packed with graphene-based sorbents. Pyriproxyfen and abamectin B1a were selected as the analytes, and orange-flavored carbonated soft drinks as the matrix. The proposed system could be successfully applied to the pyriproxyfen analysis in a concentration range between 0.5 to 25 µg/mL presenting a linearity of R2 = 0.9931 and an intra-day and inter-day accuracy of 82.2-111.4% (RSD < 13.3%) and 95.5-99.8% (RSD < 12.7%), respectively. Furthermore, the matrix composition affected the area observed for the pyriproxyfen: the higher the concentration of orange juice in the soft drink, the higher the pyriproxyfen the signal observed. Additionally, the SiGO extraction column presented a life use of 120 injections for this matrix. In contrast, the proposed system could not apply to the analysis of abamectin B1a, and the SiGO-C18ec analytical column presented significant tailing compared to a similar approach with a C18 analytical column.


Assuntos
Grafite , Dióxido de Silício , Ivermectina
3.
J Chromatogr A ; 1674: 463143, 2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35588591

RESUMO

A 25 µm i.d x 1.2 m length PS-DVB porous layer open tubular column (PLOT) was prepared and assessed in the configuration of a nano liquid chromatography coupled to an electron ionization mass spectrometry system (OT-nanoLC-EI-Ms), via the direct insertion of the column outlet into the ionization source. The developed system's operational parameters were comprehensively studied, and the setup performance was investigated employing both unidimensional and column switching configurations. As a result, the OT-nanoLC-EI-MS system demonstrated competitive applicability in separating non-amenable ESI compounds, such as polyaromatic hydrocarbons (PAHs) and non-amenable GC compounds such as thermolabile pesticides. Furthermore, with excellent chromatographic performance, the PLOT columns can work under more compatible EI-detection conditions - such as the elution with 100% organic solvent. For example, PAHs retention factors ranged between 1.5 and 2.2 for 100% MeCN mobile phase, and more than 33,000 plates per meter for naphthalene at 50 nL/min flow rate. In analyzing thermolabile pesticides, the column switching PLOT-nanoLC-EI-MS system provided LODs of 25 µg/L, demonstrating suitable intra e interday reproducibility (% RSD < 13%, n = 3), and possibilities the direct injection of raw samples with suitable robustness.


Assuntos
Praguicidas , Espectrometria de Massas por Ionização por Electrospray , Elétrons , Porosidade , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos
4.
J Chromatogr A ; 1641: 461989, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33611115

RESUMO

Open tubular liquid chromatography (OT-LC) can provide superior chromatographic performance and more favorable mass spectrometry (MS) detection conditions. These features could provide enhanced sensitivity when coupled with electrospray ionization sources (ESI-) and lead to unprecedented detection capabilities if interfaced with a highly structural informative electron ionization (EI) source. In the past, the exploitation of OT columns in liquid chromatography evolved slowly. However, the recent instrumental developments in capillary/nanoLC-MS created new opportunities in developing and applying OT-LC-MS. Currently, the analytical advantages of OT-LC-MS are mainly exploited in the fields of proteomics and biosciences analysis. Nevertheless, under the right conditions, OT-LC-MS can also offer superior chromatographic performance and enhanced sensitivity in analyzing small molecules. This review will provide an overview of the latest developments in OT-LC-MS, focusing on the wide variety of employed separation mechanisms, innovative stationary phases, emerging column fabrication technologies, and new OT formats. In the same way, the OT-LC's opportunities and shortcomings coupled to both ESI and EI will be discussed, highlighting the complementary character of those two ionization modes to expand the LC's detection boundaries in the performance of targeted and untargeted studies.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas , Escherichia coli/metabolismo , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...